type | FCN 0150N-PM-06 | FCN 0300N-PM-06 | FCN 0500N-PM-06 | FCN 0700N-PM-06 |
cutting thickness range | bis 150 mm | bis 300 mm | bis 500 mm | bis 700 mm |
cutting oxygen consumption | 33 Nm³/h | 65 Nm³/h | 77 Nm³/h | 140 Nm³/h |
cutting oxygen pressure | 10,5 bar | 10 bar | 8 bar | 10 bar |
heating oxygen consumption | 6 Nm³/h | 6 Nm³/h | 17 Nm³/h | 17 Nm³/h |
heating oxygen pressure | 0,5 bar | 0,5 bar | 2,1 bar | 2,0 bar |
heating gas consumption | 13 Nm³/h | 13 Nm³/h | 38 Nm³/h | 38 Nm³/h |
heating gas pressure | 0,4 bar | 0,4 bar | 1,9 bar | 1,9 bar |
cutting kerf | 5-6 mm | 6-8 mm | 7-9 mm | ca. 15 mm |
type | FraGa 15ES | FraGa 30E | FraGa 30ES | FraGa 50ES | FraGa 70ES |
cutting thickness range | 50-150 mm | 150-350 mm | 150-350 mm | 300-500 mm | 450-700 mm |
cutting oxygen consumption | 30 Nm³/h | 60 Nm³/h | 57 Nm³/h | 78 Nm³/h | 91 Nm³/h |
cutting oxygen pressure | 10,0 bar | 10,0 bar | 10,0 bar | 8,0 bar | 7,0 bar |
heating oxygen consumption | 9 Nm³/h | 16 Nm³/h | 9 Nm³/h | 18 Nm³/h | 16 Nm³/h |
heating oxygen pressure | 0,9 bar | 2,0 bar | 0,9 bar | 2,1 bar | 2,0 bar |
heating gas consumption | 26 Nm³/h | 24 Nm³/h | 26 Nm³/h | 35 Nm³/h | 35 Nm³/h |
heating gas pressure | 1,1 bar | 1,5 bar | 1,1 bar | 1,9 bar | 1,9 bar |
cutting kerf | 4,0 mm | 5,5 mm | 6,0 mm | 7,0 mm | 9,0 mm |
(The data refer to operation with natural gas, for values from operation with propane please contact us).
type | DB 0300N-PM-06 | DB 0600N-PM-06 |
cutting thickness range | bis 300 mm | bis 600 mm |
cutting oxygen consumption | 50 Nm³/h | 100 Nm³/h |
cutting oxygen pressure | 10 bar | 10 bar |
heating oxygen consumption | 12,5 Nm³/h | 4-11 Nm³/h |
heating oxygen pressure | 1,0 bar | 0,3-0,7 bar |
heating gas consumption | 17 Nm³/h | 6-9 Nm³/h |
heating gas pressure | 1,0 bar | 0,3-0,7 bar |
cutting kerf | 6-7 mm | 8-10 mm |
(The data refer to operation with natural gas, for values from operation with propane please contact us).
type | PB 0200N-PM-06 | PB 0300N-PM-06 | PB 0400N-PM-06 | PB 0600N-PM-06 |
cutting thickness range | bis 200 mm | bis 300 mm | bis 400 mm | bis 600 mm |
cutting oxygen consumption | 30 Nm³/h | 60 Nm³/h | 57 Nm³/h | 78 Nm³/h |
cutting oxygen pressure | 10,0 bar | 10,0 bar | 10,0 bar | 8,0 bar |
heating oxygen consumption | 9 Nm³/h | 16 Nm³/h | 9 Nm³/h | 18 Nm³/h |
heating oxygen pressure | 0,9 bar | 2,0 bar | 0,9 bar | 2,1 bar |
heating gas consumption | 26 Nm³/h | 24 Nm³/h | 26 Nm³/h | 35 Nm³/h |
heating gas pressure | 1,1 bar | 1,5 bar | 1,1 bar | 1,9 bar |
cutting kerf | 4,0 mm | 5,5 mm | 6,0 mm | 7,0 mm |
(The data refer to operation with natural gas, for values from operation with propane please contact us).
type | PB 0300N-PM12 | PB 0600N-PM12 | PB 0900N-PM-12 | PB 1200N-PM-12 |
cutting thickness range | bis 300 mm | bis 600 mm | bis 900 mm | bis 1200 mm |
cutting oxygen consumption | 35-60 Nm³/h | 60-120 Nm³/h | 140-200 Nm³/h | 200-300 Nm³/h |
cutting oxygen pressure | 5-8 bar | 7-10 bar | 10-18 bar | 18-30 bar |
heating oxygen consumption | 5-7 Nm³/h | 7-10 Nm³/h | 10-18 Nm³/h | 18-30 Nm³/h |
heating oxygen pressure | 0,2-0,3 bar | 0,3-0,5 bar | 0,4-0,6 bar | 0,6-1,0 bar |
heating gas consumption | 10-15 Nm³/h | 15-30 Nm³/h | 30-35 Nm³/h | 55-80 Nm³/h |
heating gas pressure | 0,2-0,3 bar | 0,3-0,5 bar | 0,5-0,8 bar | 0,8-1,0 bar |
cutting kerf | 5-10 mm | 10-15 mm | 15-20 mm | 18-35 mm |
(The data refer to operation with natural gas, for values from operation with propane please contact us).
type | PB 1500N-PM15 | PB 2000N-PM15 |
cutting thickness range | bis 1500 mm | bis 2000 mm |
cutting oxygen consumption | 375-440 Nm³/h | 440-500 Nm³/h |
cutting oxygen pressure | 8 bar | 7-10 bar |
heating oxygen consumption | 33 Nm³/h | 35-45 Nm³/h |
heating oxygen pressure | 0,6-1,0 bar | 0,6-1,0 bar |
heating gas consumption | 100 Nm³/h | 100-140 Nm³/h |
heating gas pressure | 1,2 bar | 1,2-1,8 bar |
cutting kerf | 25-50 mm | 30-70 mm |
(The data refer to operation with natural gas, for values from operation with propane please contact us).
type | PB 1200N-PM20 | PB 2000N-PM20 | PB 2500N-PM-20 |
cutting thickness range | bis 1200 mm | bis 2000 mm | bis 2500 mm |
cutting oxygen consumption | 220-320 Nm³/h | 375-500 Nm³/h | 450-600 Nm³/h |
cutting oxygen pressure | 7-10 bar | 5-7 bar | 5-7 bar |
heating oxygen consumption | 23-30 Nm³/h | 33 Nm³/h | 33 Nm³/h |
heating oxygen pressure | 0,2-0,3 bar | 0,3 bar | 0,3 bar |
heating gas consumption | 70-90 Nm³/h | 100 Nm³/h | 100 Nm³/h |
heating gas pressure | 0,8-1,1 bar | 1,2 bar | 1,2 bar |
cutting kerf | 15-40 mm | 25-70 mm | 65-100 mm |
Available torch models of the Prestocut 600 series
Available torch models of the Prestocut 1200 series
Available torch models of the Prestocut 1500 series
Available burner models of the GIGANT 2000 series
Of course, in addition to torches & nozzles, we also offer all other spare & wear parts for all flame cutting systems. Here is a small excerpt from our assortment - Please contact us if required!
✔ Easily exchangeable teeth
✔ Low-noise operation & long service life
✔ Long service life
✔ Significant cost reduction
✔ Suitable for all sawing systems
✔ Rapid availability
Together with a renowned manufacturer of cutting tools, a saw blade with exchangeable cutting teeth was created in a development partnership.
The carbide inserts for higher cutting speeds with higher tooth feed enable very small cutting widths. The costs for the user are significantly reduced with framag x:blade.
Do you need spare parts for one of your sawing systems? Regardless of the manufacturer and model, we are happy to offer you our expertise in equipment servicing as well as a wide range of spare parts.
An excerpt from our wide range:
For a carefree maintenance of your plant we recommend to conclude a service contract. We take care of your machine - you profit!
Our maintenance contracts are specifically tailored to your needs. Here is an excerpt of the possible services: